Eagleview Eye Clinic

Archives 2025

ASTIGMATIC FAN DIAL

An astigmatic fan dial, also known as a fan dial or astigmatic dial, is a tool used in ophthalmology and optometry for detecting and measuring astigmatism. Here’s a more detailed description:

Key Features:

  1. Radial lines: The dial consists of multiple radial lines, often in a fan-like or dial shape, with lines spaced at regular intervals (usually 10-15 degrees).
  2. Rotating dial: The dial can be rotated to different positions, allowing the practitioner to determine the axis of astigmatism.
  3. Measurement markings: The dial typically has measurement markings or degree indicators to record the axis of astigmatism.

How it works:

  1. Patient views the dial: The patient views the fan dial through a phoropter or trial frame, often with corrective lenses in place.
  2. Determine astigmatism axis: The practitioner rotates the dial while asking the patient to identify the orientation of the lines that appear clearest or most distinct.
  3. Measure astigmatism: By determining the axis of the clearest lines, the practitioner can estimate the axis of astigmatism and prescribe corrective lenses accordingly.

Purpose:

The astigmatic fan dial is used to:

  1. Detect astigmatism: Identify the presence and amount of astigmatism in a patient’s eye.
  2. Measure astigmatism: Determine the axis and amount of astigmatism to prescribe corrective lenses.
  3. Refine prescriptions: Fine-tune prescriptions for patients with astigmatism.

The astigmatic fan dial is a useful tool in ophthalmology and optometry for diagnosing and correcting astigmatism, helping practitioners provide accurate and effective treatment.

CONTRAST SENSITIVITY

Contrast sensitivity refers to the ability to detect differences in luminance or color between objects and their background. It’s a crucial aspect of visual perception, enabling us to:

  • Distinguish objects: Contrast sensitivity helps us identify objects, textures, and patterns.
  • Navigate environments: It’s essential for tasks like driving, walking, or reading.
  • Perform daily activities: Contrast sensitivity affects our ability to perform tasks that require visual detail.

Factors Affecting Contrast Sensitivity:

  • Age: Contrast sensitivity can decline with age.
  • Eye conditions: Conditions like cataracts, glaucoma, or macular degeneration can affect contrast sensitivity.
  • Neurological disorders: Certain conditions, such as multiple sclerosis or stroke, can impact contrast sensitivity.

Testing Contrast Sensitivity:

  • Pelli-Robson chart: A standardized chart used to measure contrast sensitivity.
  • Functional Acuity Contrast Test (FACT): A test that assesses contrast sensitivity at different spatial frequencies.

Improving Contrast Sensitivity:

  • Correcting underlying conditions: Treating eye conditions or updating prescriptions can help improve contrast sensitivity.
  • Visual training: Certain visual training programs can help improve contrast sensitivity in some individuals.

By understanding contrast sensitivity, we can better appreciate the complexities of visual perception and take steps to maintain healthy vision.

PELLI ROBSON CONTRAST SENSITIVITY CHART

The Pelli-Robson contrast sensitivity chart is a tool used to measure an individual’s ability to detect differences in contrast, which is essential for everyday activities like reading and driving. Here’s how it works:

Key Features:

  • Contrast Sensitivity Measurement: The chart consists of rows of letters with decreasing contrast, allowing practitioners to assess the patient’s ability to detect subtle differences in contrast.
  • Standardized Design: The chart is designed to provide a reliable and repeatable measure of contrast sensitivity.

Clinical Applications:

  • Detecting Visual Impairments: The Pelli-Robson chart can help identify visual impairments, such as cataracts, glaucoma, or age-related macular degeneration, which can affect contrast sensitivity.
  • Monitoring Treatment: It can be used to monitor the effectiveness of treatments or interventions aimed at improving contrast sensitivity.

The Pelli-Robson chart is a valuable tool for eye care professionals to assess and monitor patients’ contrast sensitivity, helping to identify potential issues and develop effective treatment plans.

DUO CHROME TEST

The duochrome test is a subjective refraction technique used in ophthalmology and optometry to refine the spherical endpoint of a patient’s prescription. It works by utilizing the principle of chromatic aberration, where different colors of light are refracted differently by the eye’s optics.

How it works:

  1. Red and Green Filters: The test involves presenting the patient with two colors, typically red and green, which are focused at slightly different points due to chromatic aberration.
  2. Comparing Clarity: The patient is asked to compare the clarity of letters or symbols on both the red and green backgrounds.
  3. Adjusting the Prescription: Based on the patient’s responses, the practitioner adjusts the spherical power to achieve equal clarity between the two colors.

Purpose:

  • Refine Spherical Correction: The duochrome test helps fine-tune the spherical component of a prescription, ensuring the most accurate correction for nearsightedness or farsightedness.
  • Confirm Endpoint: It can confirm the endpoint of a subjective refraction, providing additional assurance in the final prescription.

The duochrome test is a valuable tool in clinical practice, particularly for patients with high visual demands or those requiring precise corrections.

TRIAL LENS SET

A trial lens set is a collection of lenses used to determine the correct prescription for eyeglasses or contact lenses. These sets typically include a variety of lenses with different powers and types, such as spherical, cylindrical, and prismatic lenses.

Types of Trial Lens Sets:

  • Full-aperture trial lens sets: These sets have lenses with full apertures, allowing for unobstructed vision during exams. They often come in metal or plastic rims and may include accessory lenses.
  • Compact trial lens sets: These sets are designed to be more portable and space-efficient, making them ideal for mobile practitioners or small clinics ¹ ².

Features to Consider:

  • Lens material: Glass or high-quality plastic lenses ensure accurate and reliable results.
  • Rim material: Metal rims are durable, while plastic rims are lighter and more resistant to corrosion.
  • Number of lenses: Sets can range from a few dozen to several hundred lenses, depending on the intended use and practitioner preference.
  • Accessory lenses: Some sets include additional lenses, such as prism lenses, Maddox lenses, or occluders, to facilitate more comprehensive eye exams ¹ ² ³.

Popular Brands:

  • Veatch Ophthalmic Instruments: Known for their high-quality, full-aperture trial lens sets with metal rims.
  • Rexxam: Offers trial lens sets with plastic or metal rims, along with robust trial frames.
  • UCanSee: Provides affordable trial lens sets with high-quality lenses and durable cases.
  • Keeler: A well-established brand in the ophthalmic industry, offering trial lens sets and frames
PTERYGIUM EXCISION

Pterygium excision is a surgical procedure to remove a pterygium, a non-cancerous growth on the conjunctiva that can cause irritation, redness, and vision problems. Here’s what you need to know:

Why is it performed?

  • To restore vision by removing the growth
  • To improve cosmetic appearance
  • To relieve chronic irritation and inflammation

Surgical Techniques

  • Simple Excision: A basic method where the pterygium is removed, but it has a higher risk of recurrence (around 10%)
  • P.E.R.F.E.C.T Technique: A more advanced method involving extensive removal of Tenon’s capsule and a conjunctival transplant, with a lower recurrence rate (around 0.1%)
  • Conjunctival Autograft: A technique where a piece of healthy conjunctiva is transplanted to cover the area after pterygium removal
  • Amniotic Membrane Graft: A method using donated amniotic membrane tissue to cover the area after pterygium removal ¹ ²

What to Expect

  • The procedure usually takes less than an hour
  • Local anesthesia is used to numb the eye
  • Post-operative care includes eye drops to prevent infection and inflammation
  • Recovery time can take several weeks

Risks and Complications

  • Infection
  • Recurrence of the pterygium
  • Abnormal scarring
  • Inflammation and irritation

Benefits

  • Effective in removing the pterygium and reducing symptoms
  • Can improve vision and cosmetic appearance
  • Low risk of complications with proper care ³ ⁴
LASH EPILATION

Lash epilation refers to the removal of eyelashes, typically performed for medical or cosmetic reasons. Methods include:

  • Plucking: Removing individual lashes with tweezers.
  • Waxing: Applying wax to remove multiple lashes at once.
  • Threading: Using a thread to remove lashes.

Lash epilation can be used to:

  • Treat trichiasis: A condition where lashes grow inward, causing irritation.
  • Prepare for surgery: In some cases, lash removal may be necessary before eye surgery.
  • Cosmetic purposes: Some individuals may choose lash epilation for aesthetic reasons.

It’s essential to have lash epilation performed by a trained professional to minimize risks and ensure proper aftercare.

SCHEMATIC EYES

Schematic eyes are simplified models of the human eye that help understand its optical properties and behavior. These models are used in ophthalmology and vision science to:

  • Simplify complex optics: Schematic eyes reduce the eye’s complexity, making it easier to understand how light interacts with its various components.
  • Predict optical behavior: By simulating the eye’s optical properties, schematic eyes can predict how light will behave in different situations.
  • Educate and train: Schematic eyes are valuable tools for teaching students and professionals about the eye’s anatomy and optics.

Types of Schematic Eyes

  • Gullstrand’s Schematic Eye: A widely used model that represents the eye as a series of spherical surfaces.
  • Le Grand’s Schematic Eye: Another well-known model that includes more detailed representations of the eye’s optical components.

Applications of Schematic Eyes

  • Ophthalmic research: Schematic eyes are used to study the eye’s optical properties and behavior in various conditions.
  • Optical design: Schematic eyes help design and optimize optical systems, such as corrective lenses and surgical instruments.
  • Vision correction: Understanding the eye’s optics through schematic eyes informs the development of vision correction techniques, like LASIK surgery.

Limitations of Schematic Eyes

  • Simplifications: Schematic eyes are simplified models, which can limit their accuracy in representing individual variations.
  • Assumptions: These models rely on assumptions about the eye’s anatomy and optical properties.

Despite these limitations, schematic eyes remain valuable tools for understanding the eye’s optics and behavior.

SCHEMATIC EYES

Schematic eyes are simplified models of the human eye that help understand its optical properties and behavior. These models are used in ophthalmology and vision science to:

  • Simplify complex optics: Schematic eyes reduce the eye’s complexity, making it easier to understand how light interacts with its various components.
  • Predict optical behavior: By simulating the eye’s optical properties, schematic eyes can predict how light will behave in different situations.
  • Educate and train: Schematic eyes are valuable tools for teaching students and professionals about the eye’s anatomy and optics.

Types of Schematic Eyes

  • Gullstrand’s Schematic Eye: A widely used model that represents the eye as a series of spherical surfaces.
  • Le Grand’s Schematic Eye: Another well-known model that includes more detailed representations of the eye’s optical components.

Applications of Schematic Eyes

  • Ophthalmic research: Schematic eyes are used to study the eye’s optical properties and behavior in various conditions.
  • Optical design: Schematic eyes help design and optimize optical systems, such as corrective lenses and surgical instruments.
  • Vision correction: Understanding the eye’s optics through schematic eyes informs the development of vision correction techniques, like LASIK surgery.

Limitations of Schematic Eyes

  • Simplifications: Schematic eyes are simplified models, which can limit their accuracy in representing individual variations.
  • Assumptions: These models rely on assumptions about the eye’s anatomy and optical properties.

Despite these limitations, schematic eyes remain valuable tools for understanding the eye’s optics and behavior.

SCHEMATIC EYES

Schematic eyes are simplified models of the human eye that help understand its optical properties and behavior. These models are used in ophthalmology and vision science to:

  • Simplify complex optics: Schematic eyes reduce the eye’s complexity, making it easier to understand how light interacts with its various components.
  • Predict optical behavior: By simulating the eye’s optical properties, schematic eyes can predict how light will behave in different situations.
  • Educate and train: Schematic eyes are valuable tools for teaching students and professionals about the eye’s anatomy and optics.

Types of Schematic Eyes

  • Gullstrand’s Schematic Eye: A widely used model that represents the eye as a series of spherical surfaces.
  • Le Grand’s Schematic Eye: Another well-known model that includes more detailed representations of the eye’s optical components.

Applications of Schematic Eyes

  • Ophthalmic research: Schematic eyes are used to study the eye’s optical properties and behavior in various conditions.
  • Optical design: Schematic eyes help design and optimize optical systems, such as corrective lenses and surgical instruments.
  • Vision correction: Understanding the eye’s optics through schematic eyes informs the development of vision correction techniques, like LASIK surgery.

Limitations of Schematic Eyes

  • Simplifications: Schematic eyes are simplified models, which can limit their accuracy in representing individual variations.
  • Assumptions: These models rely on assumptions about the eye’s anatomy and optical properties.

Despite these limitations, schematic eyes remain valuable tools for understanding the eye’s optics and behavior.